SURTRON FLASH 120: Precision and Reliability for Microsurgery and Precision Procedures
Looking for a cutting-edge radiobisturi for microsurgery and precision operations? Then the SURTRON FLASH 120 is the perfect choice for you!
This innovative device with radiofrequency technology offers comprehensive features and top performance, making it the ideal tool for achieving outstanding surgical outcomes.
Precision and Flexibility at Your Fingertips:
- Programmable Operation Times: Set operation times with millisecond precision for maximum control and consistency.
- Range of Modes: Choose from a wide range of modes, including CUT, BLEND, ENHANCED, FORCED COAG, SOFT COAG, BIPOLAR COAG, and ABLATION (HF), to achieve optimal results depending on the type of procedure.
- Digital Power Display: Continuously monitor power output for absolute precision and reliability.
- Microprocessor Control: Ensure consistent and reproducible results every time.
Safety First:
- Strict Adherence to Standards: The SURTRON FLASH 120 meets the rigorous requirements of EN60601-1, EN60601-1-2, and EN60601-2-2 standards.
- Advanced Safety Features: Protect yourself and your patients with cutting-edge safety measures.
- Continuous Neutral Electrode Monitoring: Ensure proper grounding throughout the procedure.
- Safety Adapter for Bipolar Coagulation: Minimize collateral tissue damage for delicate operations.
Ergonomic Design for Comfort and Ease of Use:
- Compact and Lightweight: Maneuver the unit effortlessly even in confined spaces.
- Intuitive Controls: Navigate the device easily and keep your focus on the surgical field.
- Function Switching and Power Control from Handpiece: Perform procedures without diverting attention from the surgical field.
Technical Specifications:
- Product Code: 10300.101
- Maximum CUT Power: 120 W – 250 Ω
- Maximum BLEND Power: 90 W – 200 Ω
- Maximum ENHANCED Power: 90 W – 250 Ω
- Maximum FORCED COAG Power: 80 W – 150 Ω
- Maximum SOFT COAG Power: 60 W – 100 Ω
- Maximum BIPOLAR COAG Power: 60 W – 50 Ω
- Operating Frequency: 600 kHz
- RF Power Emission Time: 10 ms – 30 sec
- RF Power Pulse Interval: 1 – 9
- Neutral Electrode: F
- Power Supply: 115-230 Vac (selectable)
- Mains Frequency: 50-60 Hz
- Maximum Power Consumption: 300 VA
- Dimensions: 370x144x319 mm
- Weight: 6 Kg
Controls:
- Patient/Plate Circuit Control (OC)
- Emitted Power Control
- Self-Diagnosis
Safety:
- EN60601-1
- EN60601-1-2
- EN60601-2-2
- Electrical Classification: I CF
- MDR 2017/745/EU Class: II b
price on request